What it is and why choose it
The 3M Reusable 6000 Series Half-Mask Respirator is a lightweight, low-maintenance reusable facepiece designed for reliable respiratory protection in a wide range of industrial environments. Used with twin bayonet-style filters, it offers an economical and flexible solution for protection against gases, vapours and particulates, and can also be combined with the 3M S-200 Supplied-Air System for additional versatility.
Available in three sizes (6100 small, 6200 medium, 6300 large) and manufactured from hypo-allergenic thermoplastic elastomer, this half-mask provides a well-balanced, comfortable fit for extended wear.
Main features
- Flexible filter system: compatible with 3M 6000 Series gas/vapour filters and 2000 Series particulate filters, as well as combination configurations using retainer 501 and platform 603.
- Lightweight construction: facepiece weighs approximately 85 g without filters and 355 g with filters, helping to reduce wearer fatigue.
- Easy bayonet attachment: simple twin filter bayonet connection for quick, secure filter changes.
- Supplied-air option: can be used with the 3M S-200 Supplied-Air Respirator System for increased convenience and flexibility.
- Comfortable hypo-allergenic facepiece: thermoplastic elastomer facepiece with polyester/cotton elastic head harness.
- Well balanced design: twin-filter layout helps distribute weight evenly for a stable, secure fit.
- Low maintenance and economical: reusable facepiece with replaceable filters and spare parts for extended service life.
- Three sizes: 6100 (small), 6200 (medium), 6300 (large) for better fit across different users.
Technical specifications
Materials
- Facepiece: Thermoplastic elastomer
- Head harness: Polyester / cotton elastic
- Inhalation valve: Natural rubber
- Exhalation valve: Silicone rubber
- Gasket: Silicone rubber
- Filter body (6000 Series filters): Polystyrene
- Filter element (6000 Series filters): Activated / treated carbon
- Filter material (5911 / 5925 / 5935 and 2000 Series): Polypropylene
Weight
- Without filters: 85 g (approx.)
- With filters: 355 g (approx.)
Sizes
- 6100: Small
- 6200: Medium
- 6300: Large
Compatible filters and standards
The 6000 Series half-mask respirator is compatible with the following 3M filters that meet the indicated European standards:
Gas and vapour filters
- 6051 A1 (EN14387:2004) – organic vapours
- 6055 A2 (EN14387:2004) – organic vapours
- 6054 K1 (EN141:2000) – ammonia
- 6057 ABE1 (EN141:2000) – organic vapours, inorganic and acid gases
- 6059 ABEK1 (EN141:2000) – organic vapours, inorganic gases, acid gases and ammonia
- 6075 A1 & formaldehyde (EN141:2000) – organic vapours and formaldehyde
- 6096 HgP3 (EN141:2000) – mercury and particulates
Particulate filters (EN143:2000)
- 5911 P1 R
- 5925 P2 R
- 5935 P3 R
- 2125 P2 R
- 2135 P3 R
- 6035 P3 R
- 2128 P2 R
- 2138 P3 R
- 6038 P3 R
Approvals and standards
- Facepiece standard: EN140:1998 (models 6100, 6200, 6300)
- Gas/vapour filter standards: EN141:2000 (6054, 6057, 6059, 6075, 6096); EN14387:2004 (6051, 6055)
- Particulate filter standards: EN143:2000 (2125, 2128, 2135, 2138, 5911, 5925, 5935, 6035, 6038)
- CE marking: Meets Basic Safety Requirements of European Community Directive 89/686 (Articles 10 and 11B).
- Approval body for facepieces: DANTEST, ID 0200
- Quality Assurance Assessment body: BSI/UL, ID 0086
Performance and use limits
- With 6000 Series gas/vapour filters: use in concentrations of specified gases or vapours up to 10 × WEL or 1000 ppm (5000 ppm for 6055), whichever is lower (APF = 10). Not for gases/vapours with poor warning properties.
- With 5911 filter: solid and aqueous aerosols up to 4 × WEL (APF = 4).
- With 5925, 2125 or 2128 filters: particulates up to 10 × WEL (APF = 10).
- With 5935, 2135, 6035, 6038 or 2138 filters: particulates up to 20 × WEL (APF = 20).
- With 2128 and 2138: protection against ozone up to 10 × WEL (APF = 10) and relief from nuisance odours and acid gases below WEL.
- With 6038: protection against hydrogen fluoride gas up to 30 ppm and relief from ozone, organic vapours and acid gases below WEL.
- Do not use in oxygen-deficient atmospheres (below 19.5 % by volume oxygen, according to 3M definition).
- Not for unknown contaminants, poor warning properties (without supplied air), immediately dangerous to life or health, or escape purposes.
- Do not use with filters 6098 or 6099.
Cleaning and storage
- Remove gas/vapour and/or particulate filters.
- Clean the facepiece (excluding filters) with 3M 105 face seal cleaners or immerse in warm cleaning solution (max. 50 °C) and scrub with a soft brush. Neutral detergent may be added if necessary. Do not use cleaners containing lanolin or other oils.
- Rinse in fresh, warm water and allow to air dry in a non-contaminated atmosphere.
- Inspect components, especially exhalation valve and seat, before each use. Discard respirator if any part is damaged or deteriorated.
- Store the cleaned respirator away from contaminated areas when not in use, preferably in a sealed container.
Spare parts and accessories
- 6895 – 6000 Series gaskets
- 501 – Filter retainer for 5911, 5925 or 5935
- 603 – Particulate filter platform
- 105 – Facepiece cleaner
Applications and uses
When fitted with the appropriate filters, the 3M 6000 Series Half-Mask Respirator is suitable for multiple industrial applications. Selection of the correct filter type must be based on the specific contaminants and workplace exposure limits.
Typical particulate applications
- Pharmaceutical manufacturing and handling
- Powdered chemicals
- Construction and quarrying
- Ceramics
- Refractory materials
- Foundries and agriculture
- Woodworking and food industry
- Welding
- Paper industry
- Brewing
- Chemical processing
- Typical smog, inks and dyes
- Aluminium welding
Typical gas and vapour applications
- Use of conventional paints (subject to usage conditions)
- Vehicle manufacture
- Aircraft manufacture and refurbishment
- Boat building
- Ink and dye manufacture and use
- Adhesive manufacture and use
- Paint and varnish manufacture
- Resin manufacture and use
- Manufacture and maintenance of refrigeration equipment
- Agrochemicals
- Electrolytic processes
- Acid cleaning, metal pickling and metal etching
- Hospitals and laboratories (with appropriate filters, including formaldehyde and mercury/particulate combinations)
- Laboratories and particulate applications (with HgP3 filter)
Fitting instructions (summary)
- Place the respirator over the mouth and nose, then pull the harness over the crown of the head.
- Take the bottom straps in both hands, position them at the back of the neck and hook them together.
- Tighten the top straps by pulling on the ends until a comfortable, secure fit is achieved.
- Tighten the bottom straps using the front or rear adjustments. Strap tension can be reduced by pushing out on the back side of the buckles.
- Perform a positive and/or negative pressure fit check before entering the work area.
FAQ
1. Which filters can I use with the 3M 6000 Series half-mask?
The respirator is compatible with 3M 6000 Series gas/vapour filters, 2000 Series particulate filters, and 5911, 5925, 5935 particulate filters when used with platform 603 and retainer 501. It can also use combination gas/vapour and particulate configurations with retainer 501.
2. Can this mask be used with supplied air?
Yes. The 6000 Series half-mask can be used in supplied-air mode with the 3M S-200 Respirator System.
3. Is the facepiece material suitable for sensitive skin?
The facepiece is made from a hypo-allergenic thermoplastic elastomer designed to provide comfort for most users.
4. What protection factor does the mask provide with gas/vapour filters?
When fitted with 6000 Series gas/vapour filters, the facepiece may be used up to 10 × WEL or 1000 ppm (5000 ppm for 6055), whichever is lower, with an Assigned Protection Factor (APF) of 10, provided the correct filter is selected.
5. Can I use this respirator in oxygen-deficient atmospheres?
No. The respirator does not supply oxygen and must not be used in atmospheres with less than 19.5 % oxygen by volume.
6. How should I clean the 6000 Series half-mask?
Remove the filters, then clean the facepiece with 3M 105 face seal cleaners or in warm cleaning solution (max. 50 °C) using a soft brush. Rinse in warm water and allow to air dry in a clean environment.
7. What should I do if breathing becomes difficult during use?
Leave the work area immediately and check the respirator. Replace the facepiece and/or filters if damage, increased breathing resistance, dizziness, distress, taste or smell of contaminants, or irritation occurs.
8. Can I use the mask if I have facial hair?
Beards, large sideburns or other facial characteristics that interfere with the face seal may prevent an adequate fit. In such cases, satisfactory protection may not be achieved and use is not recommended.
9. Are there any filters that must not be used with this mask?
Filters 6098 and 6099 should not be used with the 6000 Series half-masks.
10. How should the mask be stored when not in use?
The respirator should be cleaned (if necessary) and stored away from contaminated areas, preferably in a sealed container.
Section 14 – Transport information
Consultar ficha técnica del fabricante.
Section 8 – Individual protection measures
Consultar ficha técnica del fabricante.