3M filter for gases, vapors, and particles, designed for use with reusable masks featuring a bayonet connection, providing respiratory protection in environments with airborne contaminants. Its key advantage is its compatibility with 3M™ reusable masks that use the bayonet filter connection system. Please consult the manufacturer's technical data sheet.

*AI-generated content*

    Presentation: Bag
    Protección: ABEK2P3
    Num. units: 2

Features

    Presentation: Bag
    Protección: ABEK2P3
    Num. units: 2

description

What it is and why choose it

The 3M gas, vapour and particulate filters with bayonet connection are designed to be used on 3M reusable half masks and full face masks equipped with the 3M bayonet filter connection. This ABEK2P3 configuration belongs to the family of filters for gases, vapours and particles, developed to offer a high level of respiratory protection when correctly selected, fitted and used for the intended application.

The bayonet connection system allows quick and secure mounting on compatible 3M reusable masks, helping to ensure a stable fit during work. According to the 3M technical data sheet, these bayonet filters are part of a complete range that includes particulate-only filters and combination filters for gases, vapours and particles, allowing you to configure the appropriate protection for different workplace contaminants.

Main features

  • Designed for use with 3M reusable half masks and full face masks fitted with 3M bayonet filter connections.
  • Part of the 3M bayonet filter family, which includes options for particles and combinations of gases, vapours and particles.
  • Filters for gases, vapours and particles in this family comply with EN 14387:2004 + A1:2008.
  • Bayonet coupling enables simple and secure attachment to the mask.
  • Respiratory protection is effective only when the product is correctly selected, fitted and worn throughout the exposure period.
  • Filter replacement for gas and vapour filters must follow an established change schedule and applicable regulations, or be carried out earlier if the contaminant can be detected inside the mask by smell or taste.
  • Plastic filter components can be cleaned with 3M Face Seal Cleaner 105; filters must not be immersed in water or liquids.

Technical specifications

  • Filter category: Gas, vapour and particulate filter with 3M bayonet connection.
  • Applicable standards (for 3M gas, vapour and combination filters with bayonet connection): EN 14387:2004 + A1:2008.
  • Compatible masks: 3M reusable masks equipped with bayonet connection (for example 3M 6000, 6500, 7500 half masks and 3M 6000 full face masks).
  • Filter type for gases and vapours in this family: Class 1 and Class 2 gas and vapour filters, and combined GasXP3 filters (see below for protection factors).

Protection factors for 3M bayonet filters (reference data)

The following nominal and assigned protection factors are given in the technical data sheet for 3M bayonet filters when used with compatible half masks and full face masks:

  • Particulate filters P1
    • With half mask: country-specific protection factor (FPN 4; UK/I FPA 4; Germany FPA 4; Italy FPA 4).
    • With full face mask: country-specific protection factor (FPN 5; UK/I FPA 4; Germany FPA 4; Italy FPA 4).
  • Particulate filters P2
    • With half mask: country-specific protection factor (FPN 12; UK/I FPA 10; Germany FPA 10; Italy FPA 10).
    • With full face mask: country-specific protection factor (FPN 16; UK/I FPA 10; Germany FPA 15; Italy FPA 15).
  • Particulate filters P3
    • With half mask: country-specific protection factor (FPN 48; UK/I FPA 20; Germany FPA 30; Italy FPA 30).
    • With full face mask: country-specific protection factor (FPN 1000; UK/I FPA 40; Germany FPA 400; Italy FPA 400).
  • Gas and vapour filters Class 1
    • With half mask: the lower of the country-specific protection factor (FPN 50; UK/I FPA 10; Germany FPA 30; Italy FPA 30) or 1000 ppm.
    • With full face mask: the lower of the country-specific protection factor (FPN 2000; UK/I FPA 20; Germany FPA 400; Italy FPA 400) or 1000 ppm.
  • Gas and vapour filters Class 2
    • With half mask: the lower of the country-specific protection factor (FPN 50; UK/I FPA 10; Germany FPA 30; Italy FPA 30) or 1000 ppm.
    • With full face mask: the lower of the country-specific protection factor (FPN 2000; UK/I FPA 20; Germany FPA 400; Italy FPA 400) or 5000 ppm.
  • Special/combined filters (GasXP3)
    • With half mask: country-specific protection factor (FPN 48; UK/I FPA 10; Germany FPA 30; Italy FPA 30).
    • With full face mask: country-specific protection factor (FPN 1000; UK/I FPA 20; Germany FPA 400; Italy FPA 400).

The nominal protection factor (FPN) is derived from the maximum total inward leakage allowed in the relevant European standards. The actual level of respiratory protection in the workplace depends on correct selection, fitting and use of the equipment, and many countries apply assigned protection factors (APF) according to EN 529:2005 and national workplace guidance.

Materials

For 3M gas, vapour and combination filters with bayonet connection, the technical data sheet indicates the following materials:

  • Adsorbent carbon.
  • Polyester.
  • Polypropylene.
  • Filter paper (for combination gas, vapour and particulate filters).

Specific material data for the 3M ABEK2P3 configuration: Consultar ficha técnica del fabricante.

Service life and storage

  • General storage life for 3M bayonet filters: up to 5 years from date of production when stored under the conditions described on the packaging.
  • Exceptions with 3-year storage life: filter models 2128, 2138 and 6038.
  • The defined storage life is indicative and a maximum value; it is subject to external factors and must not be interpreted as a guarantee.
  • Always check the expiry date before use.

Specific storage life and expiry information for 3M ABEK2P3: Consultar ficha técnica del fabricante.

Applications and use cases

These 3M bayonet filters for gases, vapours and particles are intended to be used by competent professionals who have previous experience with this type of respiratory protection product. Before using the product in any application, 3M recommends performing tests to validate the performance of the filter in the expected conditions of use.

Typical use cases for the family of gas, vapour and particulate filters include environments where both airborne particles and hazardous gases or vapours may be present, always within the limits and conditions defined by the relevant standards and national regulations. The exact suitability of the ABEK2P3 configuration for a specific contaminant or concentration must be confirmed.

Detailed application guidance for 3M ABEK2P3, including specific contaminants and concentration limits: Consultar ficha técnica del fabricante.

FAQ

Which masks are compatible with these 3M bayonet filters?

The technical data sheet specifies that 3M bayonet filters for reusable masks can be used only with 3M masks equipped with a bayonet-type connection, such as 3M 6000, 6500 and 7500 reusable half masks and 3M 6000 full face masks.

How often should I replace the gas and vapour filter?

Gas and vapour filters for 3M reusable masks must be replaced according to an established change schedule and the applicable governmental regulations, or earlier if the contaminant can be detected inside the mask by smell or taste.

When should I replace particulate filters?

Particulate filters in the 3M reusable range must be replaced when breathing becomes difficult or uncomfortable (this varies from person to person), or when the filter becomes dirty or physically damaged.

Can I clean the filter in water?

No. The product must not be immersed in water or any liquid during cleaning. Only the plastic components of the filter may be cleaned using 3M Face Seal Cleaner 105.

What standards do 3M gas, vapour and combination filters comply with?

According to the data sheet, 3M gas and vapour filters for reusable masks and 3M gas, vapour and particulate filters of the 6000 series comply with EN 14387:2004 + A1:2008.

What is the storage life of 3M bayonet filters?

The general storage life is up to 5 years from the date of production when stored under the conditions described on the packaging, except for models 2128, 2138 and 6038, which have a 3-year storage life. This value is indicative and must not be considered a guarantee.

Does correct fitting of the mask influence the protection level?

Yes. The document stresses that respiratory protection is only effective if the product is correctly selected, fitted and used throughout the entire period of exposure to respiratory hazards.

Where can I find precise technical data for the ABEK2P3 model (capacity, specific applications, etc.)?

Consultar ficha técnica del fabricante.


*Contenido generado por IA

TECHNICAL SHEET

TECHNICAL SHEET

link

SAFETY DATA SHEETS

SAFETY DATA SHEETS