WASH PRIMER CF CONVERTER

Regular price 46,78€

*VAT not included

WASH PRIMER CF CONVERTER is the converter component of Awlgrip’s chromate-free Wash Primer CF etch primer system for aluminium and stainless steel surfaces, mixed 1:1 with the yellow base OD6600. Its Controlled Fusion (CF) technology enables extended re-coat times without sanding while delivering excellent intercoat adhesion and reducing the need for high-hazard chemicals.

*Contenido generado por IA

    Presentation: Container
    Capacity: 1/4 gal
    Colour:
    Mixing ratio: 100 partes base-100 partes converter
    Base: OD6600/1QTCE - WASH PRIMER CF
    Converter: OD3300/1QTCE - WASH PRIMER CF CONVERTER

Features

    Presentation: Container
    Capacity: 1/4 gal
    Colour:
    Mixing ratio: 100 partes base-100 partes converter
    Base: OD6600/1QTCE - WASH PRIMER CF
    Converter: OD3300/1QTCE - WASH PRIMER CF CONVERTER

description

What it is and why choose it

Awlgrip WASH PRIMER CF CONVERTER (OD3300) is the converter component of the chromate-free Wash Primer CF etch primer system. Based on Controlled Fusion (CF) technology, it reacts chemically with the base component to create a tightly fused intercoat layer that delivers excellent adhesion to metal substrates, extended re-coat windows and eliminates the need for sanding between coats. The CF system removes the requirement for high-hazard chromate chemicals while maintaining high performance for professional coating applications.

Main features

  • Chromate-free etch primer system when combined with Wash Primer CF base (D6600).
  • Controlled Fusion (CF) technology providing a unique chemical reaction that ensures strong adhesion between the CF layer and subsequent coats.
  • No sanding required before applying the next coat within the recommended re-coat window.
  • Extended re-coat time: may be recoated without sanding for up to 6 months (at 25 °C and 50% RH).
  • Designed for metal substrates: suitable for aluminium, anodised aluminium and stainless steel (as part of the Wash Primer CF system).
  • Fast drying: dust-free in about 30 minutes and hard dry in about 2 hours at 25 °C / 50% RH when used in the system.
  • High VOC product supplied at maximum allowable VOC; no reduction recommended.
  • Compatible topcoats: can be overcoated with 545 Epoxy Primer and Awlgrip topcoats; not suitable under Awlgrip Fairing Compounds.

Technical specifications

  • Product type: Converter for chromate-free etch primer (Wash Primer CF system).
  • System base: Wash Primer CF Base, yellow (D6600).
  • Converter code: OD3300 / D3300.
  • Colour of system: Yellow.
  • Available pack size for converter: approx. 0.946 L (1 Quart fill volume).
  • Typical shelf life: 2 years.
  • Mixing ratio (by volume): 1 part D6600 base : 1 part D3300 converter.
  • Reduction: Not required; material is supplied at maximum allowable VOC.
  • VOC (components mixed, supplied without reducer): approx. 780 g/L.
  • VOC (converter only, D3300): approx. 908 g/L.
  • Theoretical coverage (system): approx. 10 m²/L at 14 µm dry film thickness.
  • Recommended wet film thickness (system): 50–100 µm per coat by conventional spray.
  • Recommended dry film thickness (system): 6–13 µm per coat.
  • Number of coats (system): 1 coat at 7–13 µm DFT.
  • Estimated drying at 25 °C / 50% RH (system):
    • Dust free: 30 minutes
    • Touch dry: 60 minutes
    • Hard dry: 2 hours
    • Light service / handling: 3 days
    • Full cure: 1 week
  • Pot life of mixed material at 25 °C / 50% RH: approx. 8 hours.
  • Application methods (system): air-atomized spray, brush or roller; for direct application over metal, spray is recommended.
  • Recommended spray equipment: gravity-fed conventional spray gun, 1.1–1.4 mm tip, 3–4 bar at source (depending on hose length).
  • Typical physical state of converter: paste.
  • Appearance / colour (converter): colourless, solvent odour.
  • Flash point (converter): approx. 30 °C (closed cup).
  • Density (converter): approx. 0.92 (relative density).
  • Main hazardous component: 1-methoxy-2-propanol (≥ 90% in converter mixture).

Applications and use cases

  • Professional metal priming on aluminium, anodised aluminium and stainless steel surfaces where a thin, high-adhesion etch primer is required.
  • Marine and industrial topside systems as part of multi-coat schemes using 545 Epoxy Primer and Awlgrip topcoats.
  • Fast-drying topcoat systems where quick handling and extended re-coat times are needed without sanding between coats.
  • Build systems that require increased film thickness and hiding of surface imperfections when followed by epoxy primers and Awlgrip finishing systems.
  • Situations where chromate-containing etch primers are not permitted but high performance adhesion to metal is still required.

FAQ

  1. 1. What is WASH PRIMER CF CONVERTER used for?

    It is the converter component (OD3300 / D3300) of the Wash Primer CF chromate-free etch primer system. Mixed 1:1 by volume with the D6600 yellow base, it activates the Controlled Fusion technology that provides adhesion and extended re-coat times.

  2. 2. On which substrates can the Wash Primer CF system be applied?

    The system is suitable for aluminium, anodised aluminium and stainless steel. It is not suitable for wooden or plastic surfaces.

  3. 3. Do I need to sand between coats when using this primer system?

    Within the specified re-coat window, sanding is not required before applying the next coat. The system is designed to be recoated without sanding for up to 6 months at 25 °C and 50% RH, provided the surface is clean.

  4. 4. What is the mixing ratio of base to converter?

    The mixing ratio is 1 part Wash Primer CF base (D6600) to 1 part WASH PRIMER CF CONVERTER (D3300) by volume.

  5. 5. Which topcoats can be used over the Wash Primer CF system?

    The primer can be overcoated with 545 Epoxy Primer and Awlgrip topcoats (including Awlgrip, Awlcraft 2000, Awlgrip HS and Awlcraft SE topcoats). It is not suitable for use under Awlgrip Fairing Compounds.

  6. 6. How long should I wait before putting the coated surface into service?

    Although the build system is touch dry after 24 hours at 25 °C following topcoat application, no assembly, stacking, drilling or service should take place until 2 weeks at 25 °C or 3 weeks at 13 °C to allow the Controlled Fusion process to fully activate and through-dry.

  7. 7. Do I need to thin the mixed product?

    No. Reduction is not recommended, as the material is supplied at the maximum allowable VOC.

  8. 8. How should I clean my equipment after use?

    Equipment can be cleaned using T0006 or T0002 reducers, or M.E.K.

  9. 9. What is the pot life of the mixed primer?

    The pot life of the mixed Wash Primer CF (base plus converter) is approximately 8 hours at 25 °C and 50% RH.

  10. 10. Where can I find additional performance data?

    Consultar ficha técnica del fabricante.

Section 14 – Transport information

  • UN number: UN1263.
  • Proper shipping name (ADR/RID, IMDG, IATA): PINTURAS / Paint.
  • Transport hazard class: Class 3 (Flammable liquids).
  • Packing group: III.
  • Environmental hazards: Not classified as hazardous to the environment for transport (no marine pollutant indication).
  • Special provisions (ADR): 640 (E).
  • Tunnel restriction code (ADR): (D/E).
  • Bulk transport under MARPOL Annex II / IBC Code: Not available.
  • On-site transport precautions: Transport only in closed containers kept upright and secure. Ensure personnel transporting the product know what to do in case of an accident or spillage.

Section 8 – Individual protection measures

Exposure limits

  • 1-methoxy-2-propanol (main component):
    • VLA-ED (8 h): 375 mg/m³, 100 ppm.
    • VLA-EC (15 min): 568 mg/m³, 150 ppm.
    • May be absorbed through the skin.
  • 2-methoxypropanol (trace component):
    • VLA-ED (8 h): 19 mg/m³, 5 ppm.

General hygiene measures

  • Wash hands, forearms and face thoroughly after handling the product, before eating, smoking or using the lavatory, and at the end of the working period.
  • Remove contaminated clothing and protective equipment before entering eating areas and wash them before reuse.
  • Ensure eyewash stations and safety showers are close to the work area.

Technical controls

  • Use only with adequate ventilation.
  • Use local exhaust ventilation or other engineering controls to keep airborne concentrations below occupational exposure limits and below the lower explosive limit.
  • Use explosion-proof ventilation and equipment.

Eye and face protection

  • Wear safety eyewear complying with approved standards when a risk assessment indicates exposure to liquid splashes, mists, gases or dusts.
  • If contact is possible, use safety goggles with side shields as a minimum level of protection.

Hand protection

  • Wear chemical-resistant gloves complying with EN 374.
  • Recommended materials: Viton or nitrile gloves (typical for the solvent used in this product).
  • For prolonged or repeated contact, gloves with protection class 6 (breakthrough time > 480 minutes according to EN 374) are recommended.
  • For brief contact, gloves with protection class 2 or higher (breakthrough time > 30 minutes) are recommended.
  • The final choice of gloves must consider specific workplace conditions, other chemicals handled and manufacturer instructions.

Skin and body protection

  • Select protective clothing based on the tasks performed and risks involved, and have it approved by a specialist before use.
  • Where there is a risk of ignition due to electrostatic charges, use antistatic protective clothing. For maximum protection, clothing should include antistatic coveralls, boots and gloves, in line with EN 1149.
  • Use appropriate protective footwear and any additional skin protection required for the specific application.

Respiratory protection

  • Use an air-purifying or air-supplied respirator, properly fitted and compliant with relevant standards, if risk assessment indicates it is necessary.
  • Select the respirator based on actual or expected exposure levels, product hazards and respirator performance characteristics.

Environmental exposure controls

  • Check emissions from ventilation or process equipment to ensure compliance with environmental protection legislation.
  • Where necessary, use scrubbers, filters or modify the process equipment to reduce emissions to acceptable levels.

*Contenido generado por IA

TECHNICAL SHEET

TECHNICAL SHEET

link

SAFETY DATA SHEETS

SAFETY DATA SHEETS

link

APPLICATION MANUAL

APPLICATION MANUAL

link

Recently Viewed

Ref. Amount*
OD3300/1QTCE 46,78 €
Page up

Product Quick View Popup

Vendor: Optimal

Product Type: Tops

SKU: 50-ABC

In stock Pre-order Now Sold out Order now, Only 10 left!
$400.00$300.00
Optimal Multipurpose Bootstrap 5 Html Template that will give you and your customers a smooth shopping experience which can be used for various kinds of stores such as fashion..
  • Black
  • Green
  • Orange
  • Blue
  • Red
  • XS
  • S
  • M
  • L
  • XL

Added to your shopping cart successfully.

Added to your shopping cart successfully.
Ditsy Floral Dress

Color: Gray

1 X $113.88

Total: $113.88