QUICK BUILD SEALER ACTIVATOR

Regular price 71,73€

*VAT not included

QUICK BUILD SEALER ACTIVATOR by Awlgrip is the dedicated activator for the Quick Build Sealer three-component fast-drying polyurethane primer used on interior and exterior surfaces. It is essential for achieving the required curing and full performance of the Quick Build Sealer system.

*Contenido generado por IA

    Presentation: Container
    Capacity: 1/4 gal
    Colour:
    Activador: OA3110/1QTLT - QUICK BUILD SEALER ACTIVATOR
    Converter: OU3100/1QTLT - QUICK BUILD SEALER CONVERTER

Features

    Presentation: Container
    Capacity: 1/4 gal
    Colour:
    Activador: OA3110/1QTLT - QUICK BUILD SEALER ACTIVATOR
    Converter: OU3100/1QTLT - QUICK BUILD SEALER CONVERTER

description

What is Quick Build Sealer Activator and why choose it?

Quick Build Sealer Activator (code OA3110) is the dedicated activator component for the Awlgrip Quick Build Sealer system, a two-component coating for interior and exterior use. It is a flammable, solvent-borne liquid designed for professional and industrial applications and is essential to achieve the correct curing and film performance of Quick Build Sealer. When mixed in the recommended ratio, it delivers fast drying times and reliable activation across a wide range of application conditions.

Main features

  • Essential curing component – specifically formulated to activate Awlgrip Quick Build Sealer and ensure the system reaches its designed hardness and durability.
  • For rapid coating schemes – supports the fast-drying, quick-recoat characteristics of the Quick Build Sealer system.
  • Professional-grade formulation – classified as a hazardous, flammable liquid (Flam. Liq. 3, H226) and intended for professional and industrial users only.
  • Compatible with multiple colored bases – used alongside Quick Build Sealer bases OU8000 (White), OU2000 (Black), OU5000 (Blue), OU4000 (Green), OU7000 (Red) and OU9000 (Yellow) and converter OU3100.
  • Consistent quality – supplied under strict regulatory standards (REACH, CLP) with detailed safety and handling guidance.

Technical specifications

  • Product type: Activator for two-component polyurethane primer (Quick Build Sealer system)
  • Product name: Quick Build Sealer Activator
  • Brand: Awlgrip
  • SDS code: OA3110
  • Intended use: Two-component coating for interior and exterior use (professional, industrial and consumer applications as part of the system)
  • Physical state: Liquid
  • Color: Colorless
  • Odor: Solvent
  • Boiling point: Approx. 126°C (258.8°F)
  • Flash point: 34°C (93.2°F), closed cup (Pensky-Martens)
  • Auto-ignition temperature: heptan-2-one ~393°C; 2-butoxyethyl acetate ~340°C
  • Density: approx. 0.871 g/cm³ (DIN EN ISO 2811-1)
  • Solubility in water: Not soluble in cold water
  • Lower/upper explosion limits (from n-butyl acetate): approx. 1.4% – 7.6% (v/v)
  • Vapor pressure (20°C): n-butyl acetate 11.25 mmHg (1.5 kPa); heptan-2-one 6.88 mmHg (0.92 kPa)
  • VOC (product as supplied – Quick Build Sealer mixed system): 542 g/L (4.52 lb/gal) – theoretical
  • Classification (CLP):
    • Flam. Liq. 3, H226 – Flammable liquid and vapor
    • Acute Tox. 4, H302 – Harmful if swallowed
    • Acute Tox. 4, H332 – Harmful if inhaled
    • STOT SE 3, H336 – May cause drowsiness or dizziness
    • EUH066 – Repeated exposure may cause skin dryness or cracking
  • Available pack sizes (within Quick Build Sealer range):
    • US: Activator supplied in 1 gallon containers (with White and Black Base)
    • EU/AP: Activator supplied in 1 quart containers
  • Recommended mixing ratio (Quick Build Sealer system, by volume): 4 : 1 : 1.5 (Base : Sealer Converter OU3100 : Sealer Activator OA3110)

Applications and use cases

Quick Build Sealer Activator is designed exclusively to be used as part of the Awlgrip Quick Build Sealer tricomponent primer system. Typical applications include:

  • Yacht and boat refinishing – as the activator for Quick Build Sealer on aluminium, anodized aluminium, gelcoat and fiberglass surfaces in good condition (as part of the full system).
  • Refurbishing existing coatings in good condition – activating the system to prime and seal existing finishes that have been correctly sanded and degreased.
  • Fast repair schemes – where reduced number of coats and quick overcoating with Awlcraft SE, Awlcraft 2000, Awlcraft 3000, Perfection Pro or Awlgrip Topcoat (spray) are required.
  • Interior and exterior components – any suitably prepared substrate within the Quick Build Sealer scope where a rapid, Awlgrip-quality finish is specified.

Important: Quick Build Sealer Activator must never be used as a standalone coating. It is solely for use in the specified mixing ratio with Quick Build Sealer base and converter.

FAQ – Quick Build Sealer Activator

  1. Is Quick Build Sealer Activator essential for the Quick Build system?

    Yes. The activator is essential for the technology of the product to achieve the required curing and performance of Quick Build Sealer.

  2. What is the correct mixing ratio with Quick Build Sealer?

    Mix by volume 4:1:1.5 (Base : Sealer Converter OU3100 : Sealer Activator OA3110). No induction time is required.

  3. Do I need to thin the activated mixture?

    Quick Build does not require reduction. However, 5–10% Awlgrip Reducers (T0001, T0002, T0003, T0005) can be added to ease the application experience.

  4. On which substrates can the activated Quick Build Sealer be applied?

    Quick Build Sealer (activated with OA3110 and converter) may be applied directly to aluminium, anodized aluminium, gelcoat, fiberglass and existing coatings in good condition, following the specified sanding and degreasing steps.

  5. What are the recommended drying and overcoating times of the Quick Build Sealer system?

    At 25°C (77°F), typical values are: touch dry about 45 minutes, hard dry about 7 hours, pot life about 5 hours. Overcoating with Awlcraft 2000, Awlcraft 3000, Awlcraft SE, Awlgrip Topcoat or Perfection Pro by spray is possible from 15 minutes up to 24 hours (4 hours maximum at 35°C). Times vary with temperature.

  6. Is the activator suitable for consumer use?

    The system is described for professional, industrial and consumer use, but the product is hazardous and flammable. It should only be handled by persons trained to deal with solvent-borne, two-component coatings and who can follow all safety instructions.

  7. Can I apply the activated product at any temperature?

    No. Paint materials should not be applied to surfaces less than 3°C (5°F) above the dew point, to surfaces warmer than 41°C (105°F), or when ambient temperature is below 10°C (50°F) or above 41°C (105°F).

  8. How should unused product and waste be disposed of?

    Waste and residues should be disposed of via a licensed waste disposal contractor, following all local, regional and national regulations. Do not allow the product to enter drains or watercourses. Empty containers may retain flammable vapors and must be handled and disposed of with care.

  9. What should I do if the activator is inhaled or swallowed?

    Move the person to fresh air and seek medical attention. If swallowed, rinse mouth with water and get medical attention; do not induce vomiting unless directed by medical personnel. See the Safety Data Sheet for full first-aid instructions.

  10. Where can I find additional technical data?

    Consultar ficha técnica del fabricante.

Section 14 – Transport information

  • UN number / ID number: UN1263
  • UN proper shipping name: PAINT RELATED MATERIAL
  • Transport hazard class: Class 3 (flammable liquid)
  • Packing group: III
  • Environmental hazards: Not classified as hazardous to the environment for transport (not a marine pollutant).
  • ADR/RID tunnel code: (D/E)
  • IMDG emergency schedules: F-E, S-E
  • Special precautions for user: Transport within the user’s premises only in closed, upright and secure containers. Ensure personnel involved in transport know what to do in case of an accident or spillage.
  • Transport in bulk according to IMO instruments: Not applicable.

Section 8 – Personal protection measures

The following information is summarized from the Safety Data Sheet and applies to handling Quick Build Sealer Activator and the mixed coating in professional and industrial environments.

Exposure controls

  • Engineering controls: Use only with adequate ventilation. Employ local exhaust ventilation, process enclosures or other engineering controls to keep airborne concentrations below occupational exposure limits and below lower explosive limits. Use explosion-proof ventilation equipment.
  • Environmental controls: Emissions from ventilation or process equipment must comply with environmental protection legislation. Fume scrubbers, filters or equipment modifications may be required to reduce emissions.

Personal protective equipment (PPE)

General hygiene

  • Do not eat, drink or smoke in areas where the product is handled, stored or processed.
  • Wash hands, forearms and face thoroughly after handling and before breaks.
  • Remove contaminated clothing and protective equipment before entering eating areas and wash contaminated garments before reuse.
  • Ensure eyewash stations and safety showers are close to workstations.

Eye and face protection

  • Use safety eyewear complying with an approved standard.
  • Where splashes are possible, wear safety glasses with side shields as a minimum, unless a higher level of protection is indicated by risk assessment.

Hand protection

  • Wear chemical-resistant, impervious gloves complying with EN374 or equivalent.
  • For prolonged or frequently repeated contact: gloves with protection class 6 (breakthrough time >480 minutes). Recommended: Viton or nitrile, thickness ≥ 0.38 mm.
  • For expected brief contact: gloves with protection class ≥ 2 (breakthrough time >30 minutes). Recommended: nitrile, thickness ≥ 0.12 mm.
  • Replace gloves regularly and immediately if damaged. Performance may be reduced by physical or chemical damage or poor maintenance.

Body and skin protection

  • Select protective clothing based on the tasks and associated risks, and have it approved by a specialist.
  • Where there is a risk of ignition from static electricity, wear anti-static protective clothing. For maximum protection, clothing should include anti-static overalls, boots and gloves (refer to EN 1149).
  • Use appropriate footwear and additional skin protection as required by the risk assessment.

Respiratory protection

  • Select a respirator that meets the appropriate standard or certification, based on the hazard and exposure potential.
  • Respirators must be used as part of a respiratory protection program ensuring correct fit and training.
  • For operations such as sanding, spraying, cutting or welding where exposure cannot be adequately controlled by ventilation, use a respirator conforming to EN140 with type A/P2 filter or better.

*Contenido generado por IA

TECHNICAL SHEET

TECHNICAL SHEET

link

SAFETY DATA SHEETS

SAFETY DATA SHEETS

link

APPLICATION MANUAL

APPLICATION MANUAL

link

Recently Viewed

Ref. Amount*
OA3110/1QTLT 71,73 €
Page up

Product Quick View Popup

Vendor: Optimal

Product Type: Tops

SKU: 50-ABC

In stock Pre-order Now Sold out Order now, Only 10 left!
$400.00$300.00
Optimal Multipurpose Bootstrap 5 Html Template that will give you and your customers a smooth shopping experience which can be used for various kinds of stores such as fashion..
  • Black
  • Green
  • Orange
  • Blue
  • Red
  • XS
  • S
  • M
  • L
  • XL

Added to your shopping cart successfully.

Added to your shopping cart successfully.
Ditsy Floral Dress

Color: Gray

1 X $113.88

Total: $113.88