INTERBOND 1202 UPC PART A KIT INDIVISIBLE

Regular price 1.168,80€

*VAT not included

Interbond 1202UPC Part A is a two-component, ambient-cure, inorganic universal pipe coating designed for long-term corrosion protection of above-ground carbon or stainless steel piping and accessories operating between -196ºC (-321ºF) and +650ºC (1202ºF). It simplifies coating specifications for process piping by allowing two-coat or single-coat applications and conforms to the inert multi-polymeric matrix coating definition per NACE SP0198.

*Contenido generado por IA

    Capacity: 14,48 l
    Colour:

Features

    Capacity: 14,48 l
    Colour:

description

What is Interbond 1202 UPC Part A Kit Indivisible and why choose it

Interbond 1202 UPC Part A is the base component of a two-component, high-performance Universal Pipe Coating (UPC) from International (AkzoNobel), designed for the protection of process piping and accessories working from cryogenic to high operating temperatures. When mixed with its dedicated Part B hardener, it forms an inorganic copolymer coating that delivers long-term corrosion protection and temperature resistance for above-ground steel piping, both insulated and uninsulated.

This product is typically selected to simplify pipe coating specifications, reduce the number of different products required on a project and provide reliable performance in demanding onshore and offshore industrial environments.

Main features

  • Two-component inorganic copolymer system (Part A base + dedicated Part B hardener).
  • Designed as a Universal Pipe Coating (UPC) for process pipelines and associated equipment.
  • Suitable for use on carbon steel and stainless steel substrates.
  • Intended for above-ground piping, including insulated and uninsulated lines (not for buried service or immersion unless specifically stated by the manufacturer).
  • Formulated for long-term corrosion protection across a wide operating temperature range (information based on manufacturer literature, but exact limits should be confirmed in the latest official technical data sheet).
  • Single- or two-coat system capability, helping reduce coating complexity on new construction projects.
  • Metallic grey, matt finish (typical for the Interbond 1202 UPC system; slight variations may exist between markets or batches).
  • Compatible with airless spray and other professional application methods commonly used in industrial coating shops.

Technical specifications

Important: The following data are indicative and based on publicly available manufacturer literature for Interbond 1202 UPC. They may not be fully updated or specific to the exact packaging variant "Part A Kit Indivisible". Always verify against the most recent official technical data sheet from International.

  • Product type: Two-component, titanium-modified inorganic copolymer universal pipe coating (Part A is the base component).
  • Typical colour: Metallic grey (unverified for this exact kit; check label).
  • Gloss level: Matt.
  • Volume solids: Typically around 56–64% by volume (value may vary by regional formulation; not fully verified for this kit).
  • Recommended dry film thickness (DFT): Approx. 100–200 μm per coat, depending on specification (check project specification and current data sheet).
  • Typical application methods: Airless spray, conventional/air spray; brush or roller generally for small areas and touch-up only.
  • Typical touch dry / handling times: Fast drying at ambient temperature; exact times depend on temperature and film thickness and must be taken from the latest technical data sheet.
  • Flash point: Both components and the mixed product are flammable; exact flash point values must be confirmed in the current safety and technical documentation.

Applications and use cases

  • Process plant piping: Corrosion protection of new construction process lines in refineries, petrochemical plants, gas processing facilities and similar industrial installations.
  • Cryogenic service: Protection of cryogenic piping and equipment where resistance to very low temperatures is required (confirm suitability and limits for each project with the latest technical data sheet).
  • High-temperature lines: Piping and accessories that operate at elevated temperatures where conventional epoxy coatings may not be suitable.
  • Insulated and uninsulated piping: Lines that will remain bare or be covered with thermal insulation, including typical process and utility lines above ground.
  • Valves and accessories: Use as a single specification coating for valves, supports, instruments and OEM items to streamline coating systems on complex pipe racks.

FAQ – Interbond 1202 UPC Part A Kit Indivisible

  1. Is Interbond 1202 UPC Part A usable on its own?

    No. Part A is only the base component. It must be mixed with the correct Part B hardener in the specified mixing ratio before application. Use of Part A alone will not cure properly and will not provide the intended protection.

  2. What surfaces can be coated with Interbond 1202 UPC?

    It is intended mainly for properly prepared carbon steel and stainless steel surfaces. Surface preparation, including abrasive blast cleaning and cleanliness standards, must follow the latest International specification and project requirements.

  3. Can it be used below ground or in immersion service?

    Interbond 1202 UPC is generally described as an above-ground universal pipe coating and is typically not specified for buried or permanent immersion service. Any such use must be confirmed as suitable in the most recent official technical data sheet and project coating specification.

  4. What is the operating temperature range?

    Public manufacturer information indicates that the Interbond 1202 UPC system can be used from cryogenic up to high temperatures. However, exact minimum and maximum service temperatures for your region and specification must be verified in the latest data sheet, as they can depend on system design and local approvals.

  5. How many coats are normally required?

    Many specifications use one or two coats of Interbond 1202 UPC to achieve the required total dry film thickness. The number of coats depends on project requirements and application method.

  6. Is it suitable for use under insulation?

    Yes, one common use is for piping that will be thermally insulated. Always ensure that the coating system and specified dry film thickness meet the project design for corrosion under insulation (CUI) mitigation.

  7. How should the kit be mixed and applied?

    The exact mixing ratio, induction time (if any), pot life and application parameters (nozzle size, pressure, thinning) are defined in the official technical data sheet and product label. These details are not fully verified here and must be followed exactly as per International’s current instructions.

  8. What is meant by "Kit indivisible"?

    "Kit indivisible" typically means that the supplied Part A and Part B volumes form a complete set designed to be used together and should not be split or proportioned into smaller separate kits, to avoid mixing errors. This description is generic and should be confirmed on the product packaging.

  9. Where can I find fully confirmed data for this product?

    All critical information such as exact mixing ratio, flash point, VOC content, curing times, temperature limits, surface preparation and recoat intervals must be taken from the latest official technical data sheet and safety data sheet provided by International / AkzoNobel.

Section 14 – Transport information (not fully verified)

Important disclaimer: The specific transport classification for "INTERBOND 1202 UPC PART A KIT INDIVISIBLE" (for example UN number, proper shipping name, hazard class, packing group and any marine pollutant status) is not fully verified here. The information below is generic guidance only and does not replace the official Safety Data Sheet (SDS).

  • Interbond 1202 UPC Part A is a solvent-containing industrial coating component and is likely to be classified as a dangerous good for transport by road, sea and air.
  • Typical regulations that may apply: ADR/RID (road/rail), IMDG (sea) and IATA/ICAO (air). Exact classification details must be taken from the current SDS.
  • Packaging should remain closed and upright, protected from physical damage, heat sources and direct sunlight during transport.
  • Spill response materials should be available during loading/unloading (e.g. absorbents and non-sparking tools), in line with the SDS recommendations.
  • Only trained personnel should handle transport, in compliance with local and international dangerous goods regulations.

For correct and legally compliant transport information (including proper shipping name, UN number, hazard class, packing group and environmental hazards), always consult the latest official Safety Data Sheet for Interbond 1202 UPC Part A issued by International / AkzoNobel.

Section 8 – Individual protection measures (not fully verified)

Important disclaimer: The exact personal protective equipment (PPE) required for "INTERBOND 1202 UPC PART A KIT INDIVISIBLE" must be taken from the official SDS. The following measures are typical for solvent-borne industrial coatings and are only indicative.

  • General hygiene: Avoid contact with skin, eyes and clothing. Do not breathe vapours or spray mist. Do not eat, drink or smoke during use. Wash hands and face thoroughly after handling.
  • Respiratory protection: In spray application or poorly ventilated areas, use suitable respiratory protection approved for organic vapours and particulate aerosols, as specified in the SDS and in accordance with local regulations.
  • Hand protection: Wear chemical-resistant gloves (for example, nitrile or other solvent-resistant material) with breakthrough times suitable for the solvents present. Glove selection must follow the SDS and manufacturer recommendations.
  • Eye and face protection: Use safety goggles or a face shield providing side protection against splashes and spray mist.
  • Skin and body protection: Wear suitable protective clothing such as solvent-resistant overalls. For spray application, consider additional protection such as hooded coveralls.
  • Engineering controls: Ensure adequate ventilation in application and drying areas. Use local exhaust ventilation where necessary to keep solvent vapour concentrations below occupational exposure limits.
  • Environmental precautions: Prevent uncontrolled release to drains or the environment. Collect spills with suitable absorbent material and dispose of waste in accordance with local regulations and the SDS.

Because detailed composition, exposure limits and exact PPE requirements are not fully verified here, it is essential to consult and follow the latest official Safety Data Sheet for Interbond 1202 UPC Part A for comprehensive protective measures.

*Contenido generado por IA

TECHNICAL SHEET

TECHNICAL SHEET

link

SAFETY DATA SHEETS

SAFETY DATA SHEETS

link
Ref. Amount*
HTA160/20LT/EU 1.168,80 €
Page up

Product quick view

Vendor: Optimal

Product Type: Tops

SKU: 50-ABC

In stock Pre-order Now Sold out Order now, Only 10 left!
$400.00$300.00
Optimal Multipurpose Bootstrap 5 Html Template that will give you and your customers a smooth shopping experience which can be used for various kinds of stores such as fashion..
  • Black
  • Green
  • Orange
  • Blue
  • Red
  • XS
  • S
  • M
  • L
  • XL

Added to your shopping cart successfully.

Added to your shopping cart successfully.
Ditsy Floral Dress

Color: Gray

1 X $113.88

Total: $113.88