What is the Elcometer Soluble Salt Profile Tester and why choose it
The Elcometer Soluble Salt Profile Tester (Elcometer 130 SSP) is a robust, fully portable gauge designed to measure the level and density of soluble salts on surfaces quickly and accurately. Tested in accordance with ISO 8502-9 as an equivalent method to the Bresle patch, it delivers results more than four times faster than traditional Bresle testing. A single test covers an area equivalent to four Bresle patches and provides detailed 2D and 3D salt profile maps, enabling fast, informed decisions about surface cleanliness before coating.
Main features
- Measures soluble salt level and density more than four times faster than equivalent Bresle methods.
- Each filter paper is the size of four Bresle patches, giving four Bresle-equivalent readings in about 2½ minutes.
- Multi-point conductivity sensor displays the salt density trend as a detailed density map.
- Large colour LCD shows readings in µg/cm², mg/m², ppm, µS/cm, mS/cm and % salinity.
- Pass/fail indication based on user-defined limits.
- 2D salt density maps with high/low readings and 3D salt density profiles with maximum salt concentration (Hi).
- Automatic temperature compensation for reliable measurements in varying climatic conditions.
- Water compensation function for accurate, repeatable readings when using non-pure water.
- Stores up to 3,500 sets of readings in 1,000 user-definable alphanumeric batches.
- On-screen statistics including number of readings, mean, standard deviation, highest and lowest values, coefficient of variation and number of readings above high limit.
- Graphs on the gauge: trend graph (last 20 readings), batch review graph and analogue bar graph.
- Wireless data output via Bluetooth to PC, Android and iOS devices, plus USB connection to PC.
- Compatible with ElcoMaster software for instant report generation, data management and cloud collaboration.
- Rugged, impact, water and dust resistant body, equivalent to IP64.
- Scratch and solvent resistant 2.4" (6 cm) TFT colour display with permanent backlight.
- Ambient light sensor with automatic brightness adjustment and emergency light mode.
- Magnetic or tripod mounting options.
- Calibration verification mode with optional certified calibration tile; calibration verification date can be recorded for reporting.
- Supplied with a plastic carrying case and a comprehensive starter kit including magnetic disks, high purity test papers, pure water, syringes, tweezers, disposable gloves and sensor cleaning wipes.
Technical specifications
Measurement performance
- Repeatable and reproducible measurements.
- Menu structure available in over 30 languages.
- Gauge accuracy: ±1% of reading.
Measurement modes and ranges
- Surface cleanliness – Elcometer 130 mode: 0–50 µg/cm²; 0–500 mg/m².
- Surface cleanliness – Bresle equivalent method mode: 0–15 µg/cm²; 0–150 mg/m².
- Conductivity: 0–6000 µS/cm; 0–6 mS/cm.
- Salinity: 0–3000 ppm; 0–0.3%.
Resolution
- Surface cleanliness: 0.1 µg/cm²; 1 mg/m².
- Conductivity: 1 µS/cm; 0.001 mS/cm; 1 ppm; 0.0001% salinity.
Gauge functions
- Measurement modes: Surface cleanliness, Conductivity, Calibration in compensation mode.
- Automatic temperature compensation.
- Readings and salt profile maps stored with date and time stamp.
- Batch size lock mode with batch linking.
- Delete last reading function.
- Gauge-specific and batch-specific limits.
- Review, copy, delete and clear batches and calibration settings.
Memory
- Readings: 3,500 sets of individual readings, including salt density, pass/fail map and distribution graph.
- Batches: up to 1,000.
- Batches can be named with user-definable alphanumeric identifiers directly on the gauge.
Operating conditions and power
- Operating temperature range: 5°C to 40°C (41°F to 104°F).
- Power supply: 4 x AA batteries or via USB (rechargeable cells may also be used).
- Battery life (approx.): 30 hours with alkaline batteries; 45 hours with lithium batteries.
Sample and timing
- Sample time: 2 minutes.
- Sample size: circular test area of 110 mm (4.3").
Physical characteristics
- Dimensions: 250 x 145 x 50 mm (9.8 x 5.7 x 1.9").
- Weight: 780 g (1.72 lb).
- Ingress protection: impact, water and dust resistant, equivalent to IP64.
Standards compliance
- SSPC Guide 15.
- Equivalent to Bresle ISO 8502-9 test method.
Supplied items (packing list)
- Elcometer Soluble Salt Profile Tester.
- 3 magnetic disks.
- 100 high purity test papers.
- 250 ml bottle of pure water.
- 20 PVC storage bags.
- Disposable gloves.
- Sensor cleaning wipes.
- 3 syringes of 3.0 ml.
- 2 plastic tweezers.
- 4 AA batteries.
- Shoulder strap.
- Plastic carrying case.
- Test certificate and instruction manual.
- USB cable.
- ElcoMaster software.
Available accessories
- Certified calibration verification tile.
- Magnetic disks (pack of 3).
- 3.0 ml syringes (pack of 3).
- Polyethylene zip bags (pack of 20).
- Pure water – 250 ml bottle with 3 ml syringe.
- Pure water – 1000 ml bottle with 3 ml syringe.
- High purity test papers (pack of 100).
- Disposable vinyl gloves (pack of 20).
- Plastic tweezers (pack of 2).
- Box of 72 sensor cleaning wipes.
- USB Bluetooth adapter V2.1+.
Applications and use cases
- Fast assessment of surface cleanliness prior to coating, where soluble salt contamination must be controlled.
- Field inspections requiring rapid, repeatable measurements in harsh or outdoor environments, using the IP64-resistant handheld design.
- Quality control in blasting and surface preparation, using 2D and 3D salt density maps to locate high contamination areas outside user-defined limits.
- Laboratory comparison work where Bresle-equivalent measurements are required according to ISO 8502-9.
- Integrated inspection reporting combining soluble salt contamination data with surface profile, climate and dry film thickness results via ElcoMaster software.
FAQ
How fast is the Elcometer Soluble Salt Profile Tester compared with Bresle patches?
Each test covers an area equivalent to four Bresle patches and provides four Bresle-equivalent readings in about 2½ minutes, more than four times faster than traditional Bresle methods.
What measurement units can the gauge display?
The large colour LCD can display results in µg/cm², mg/m², ppm, µS/cm, mS/cm and % salinity.
Does the instrument compensate for temperature variations?
Yes, it has automatic temperature compensation to ensure accurate results under different climatic conditions.
How many readings can be stored?
The gauge can store up to 3,500 sets of individual readings in 1,000 user-definable alphanumeric batches.
Is the Elcometer Soluble Salt Profile Tester equivalent to the Bresle method?
Yes, it has been laboratory tested in accordance with ISO 8502-9 and provides measurements equivalent to the Bresle patch method.
Can I transfer data to a computer or mobile device?
Yes, data can be transferred via USB to a PC or wirelessly via Bluetooth to PCs and compatible Android and iOS devices, and then managed with ElcoMaster software.
What kind of environment is the gauge designed for?
The tester is impact, water and dust resistant to IP64 equivalent, making it suitable for demanding field and site environments.
What comes included with the instrument?
It is supplied with magnetic disks, high purity test papers, pure water, syringes, disposable gloves, tweezers, sensor cleaning wipes, batteries, shoulder strap, plastic carrying case, USB cable, ElcoMaster software, and documentation.
Is there a way to verify calibration in the field?
Yes, an optional certified calibration verification tile is available, and the gauge includes a calibration verification mode to check accuracy during field work.
Individual protection measures (Section 8)
When using the Elcometer Soluble Salt Profile Tester, the use of clean disposable gloves is included in the procedure. The instrument is supplied with disposable vinyl gloves to help prevent contamination of the test area and consumables during handling and testing.
*Contenido generado por IA