What it is and why choose it
The PCE-CT 80-FN1D5 THICKEMETER from PCE INSTRUMENTS is a precision coating thickness gauge designed for accurate measurement of plastics, paints and other coatings on both ferrous (Fe) and non-ferrous (NFe) metal substrates. It combines an ergonomic handheld instrument with a robust spring-loaded probe and V-groove, allowing reliable measurements on flat, convex and concave surfaces. With a wide measurement range for Fe and NFe, internal data memory for up to 2000 readings and an adjustable alarm with LED indication, this thickness meter is particularly suitable for quality control and incoming goods inspection.
The instrument features a rubber-coated housing for additional protection of the electronics, automatic substrate detection and a statistical function to evaluate measurement series directly on the device.
Main features
- Coating thickness gauge for coatings on ferrous (Fe) and non-ferrous (NFe) metals.
- Wide measuring range for Fe and NFe substrates suitable for many coating tasks.
- Probe with V-groove to measure reliably on convex and concave surfaces.
- Robust, spring-loaded probe head for precise, repeatable measurements.
- Insensitive to vibrations during measurement.
- Ergonomic design for comfortable handheld use.
- Visual alarm with green LED when values are within limits and red LED when limits are exceeded.
- Adjustable upper and lower alarm thresholds.
- Internal memory for up to 2000 measured values in automatic logging mode.
- USB 2.0 interface for data transfer to a PC.
- Optional analysis software for data export in *.csv format (accessory PCE-CT 80SW).
- Multiple calibration options including multi-point and zero calibration.
- Rubber-coated housing for improved impact protection.
Technical specifications
Model
- Designation: PCE-CT 80-FN1D5
- Type: Coating thickness meter for Fe and NFe substrates
Measurement ranges
- Ferrous (Fe): 0 … 1500 µm
- Non-ferrous (NFe): 0 … 1500 µm
Resolution
- 0.1 µm for values < 100 µm
- 1 µm for values > 100 µm
Accuracy
Probe
- Probe diameter: Ø 17 mm
- V-groove in the probe head for convex surfaces
- Spring-loaded, robust probe design
- Cable length: 1 m
Materials and substrates
- Coatings on ferrous metals (Fe)
- Electrically non-conductive coatings on non-ferrous metals (NFe)
- Minimum substrate thickness: 0.2 mm for Fe substrates / 0.05 mm for NFe substrates
Geometry requirements
- Minimum convex radius: 5 mm
- Minimum concave radius: 25 mm
- Minimum measurement area: Ø 17 mm
Measurement and calibration
- Probe mode: Automatic Fe + NFe detection / Magnetic induction (Fe) / Eddy current (NFe)
- Measurement mode: Single measurement
- Calibration: Multi-point calibration (1 … 4 points per group) and zero calibration
- Measurement units: µm / mm / mils
Data logging and statistics
- Interface: USB 2.0
- Memory:
- 1 volatile measurement group in DIR mode
- 4 non-volatile groups with automatic logging and up to 2000 values in GEN mode
- Statistical functions: Number of readings, average value, maximum value, minimum value, standard deviation
Alarms and display
- Alarm indication when lower or upper alarm level is exceeded
- Display type: LCD, 128 x 128 pixels
- Additional indicators: Battery status and error detection
Power supply and operating conditions
- Power supply: 3 x 1.5 V AAA batteries
- Auto power-off: After 3 minutes of inactivity
- Operating temperature: 0 … +50 ºC
- Operating humidity: 20 … 90 % RH, non-condensing
- Storage temperature: -10 … +60 ºC
- Storage humidity: 20 … 90 % RH, non-condensing
Physical characteristics
- Dimensions: 143 x 71 x 37 mm
- Weight: 271 g (with sensor and batteries)
- Housing: Rubber-coated for added protection
Scope of delivery
- 1 x Coating thickness meter
- 1 x Sensor (model-dependent)
- 1 x Set of calibration standards
- 2 x Calibration bases Fe and NFe
- 3 x 1.5 V AAA batteries
- 1 x Transport case
- 1 x User manual
Optional accessories
- CAL-CT: ISO calibration certificate
- PCE-CT 80SW: Software with data cable
- PCE-CT Shims 50-1000µm: Set of 5 calibration foils, 50 … 1000 µm
- PCE-CT Shims 100-4000µm: Set of 5 calibration foils, 100 … 4000 µm
- PCE-CT Shims Fe-NFe Set 50-1000µm: Set of 5 calibration foils, 50 … 1000 µm with Fe and NFe bases
Applications and use cases
- Quality control of coating thickness on ferrous and non-ferrous metal components.
- Incoming goods inspection to verify coating specifications on supplied parts.
- Measurement of paint, plastic and other non-conductive coatings on metal substrates.
- Control of coating processes where convex or concave surfaces must be checked using the V-groove probe.
FAQ
1. What substrates can I measure with the PCE-CT 80-FN1D5?
The instrument is suitable for coatings on ferrous metals (Fe) and for electrically non-conductive coatings on non-ferrous metals (NFe).
2. What is the maximum coating thickness that can be measured?
For the PCE-CT 80-FN1D5, the measuring range is 0 … 1500 µm on both Fe and NFe substrates.
3. How many readings can be stored in the device?
In GEN mode, up to 2000 measurement values can be stored in four non-volatile groups with automatic logging. There is also one volatile group in DIR mode.
4. Can the device distinguish automatically between Fe and NFe substrates?
Yes, the probe supports automatic detection of Fe and NFe substrates and uses magnetic induction for Fe and eddy current for NFe.
5. What calibration options are available?
The meter allows multi-point calibration with 1 to 4 points per group as well as zero calibration. A set of calibration standards and Fe/NFe bases is included.
6. Is software available for data analysis?
Yes, optional software with data cable (PCE-CT 80SW) is available and allows exporting measurement data in *.csv format.
7. What kind of alarm indication does the instrument have?
Upper and lower alarm thresholds can be set. A green LED indicates that readings are within the defined range, while a red LED lights up when values are outside the limits.
8. On which surface geometries can measurements be taken?
Measurements can be carried out on flat surfaces, as well as on convex surfaces with a minimum radius of 5 mm and concave surfaces with a minimum radius of 25 mm, provided the measurement area is at least Ø 17 mm.
9. How is the instrument powered and how long does it stay on?
The thickness meter is powered by three 1.5 V AAA batteries and switches off automatically after 3 minutes of inactivity.
10. What protection does the housing offer?
The housing is coated with rubber to provide additional protection for the electronics against impacts.
Section 14 – Transport information
Information not provided by the manufacturer.
Section 8 – Individual protection measures
Information not provided by the manufacturer.
*Contenido generado por IA